| Name | vmvasp_86_082_r1952017004_0 |
| Workunit | 3628 |
| Created | 1 Oct 2023, 20:53:15 UTC |
| Sent | 1 Oct 2023, 21:59:04 UTC |
| Report deadline | 4 Oct 2023, 21:59:04 UTC |
| Received | 1 Oct 2023, 22:20:01 UTC |
| Server state | Over |
| Outcome | Computation error |
| Client state | Compute error |
| Exit status | 1 (0x00000001) Unknown error code |
| Computer ID | 128 |
| Run time | 18 sec |
| CPU time | |
| Validate state | Invalid |
| Credit | 0.00 |
| Device peak FLOPS | 4.41 GFLOPS |
| Application version | Virtual Machine with 6 GB available memory v1.01 (vbox64_60_6G) windows_x86_64 |
| Peak working set size | 11.11 MB |
| Peak swap size | 6.23 MB |
| Peak disk usage | 1.74 GB |
<core_client_version>7.20.2</core_client_version>
<![CDATA[
<message>
Fonction incorrecte.
(0x1) - exit code 1 (0x1)</message>
<stderr_txt>
Resolving File Names...
Making object of control of VM ...
Starting VM-constructor...
Getting environment variable...
VBOX_MSI_INSTALL_PATH=C:\Program Files\Oracle\VirtualBox\
vbox_manage executable = "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe"
Begin GetCurrentPath...
Buf memory was allocated.
Current directiry is C:\ProgramData\BOINC\slots\32.
Current Path = C:\ProgramData\BOINC\slots\32
Setting pathes with brackets.
Checking existantion of files...
Custimization VM-control object...
Checking VBOX...
Checking errors...
Setting checkpoint period to 3600...
Checkpoint was not found.
Virtual Machine USPEX_VMVASP_52769183 exists. Removing it.
There are no VMs from previous tasks with name USPEX_VMVASP_52769183.
Searching inaccessible VMS and checking it.
Checking inaccessible VM with UUID: {a72b1f53-380f-41aa-8c29-f84b4ea42fd3}
Checking inaccessible VM with UUID: {340ddaf7-78a8-4e52-bd4b-dd5ccff26b68}
Checking inaccessible VM with UUID: {4e9c6bbc-f114-4acb-b1dc-c29c44025848}
Checking inaccessible VM with UUID: {718c635f-17ce-4c0c-b6d1-2ec7e4787f36}
Checking inaccessible VM with UUID: {cfd3f84c-6f23-480a-ae9d-33de75688b97}
Checking inaccessible VM with UUID: {7f3af74d-4c95-4c42-9cdd-7facdbaf1785}
Checking inaccessible VM with UUID: {5a714396-d911-47b9-bc4c-021d1762cdb0}
Checking inaccessible VM with UUID: {d4921363-9025-46c1-8e8b-ad36e63090b6}
Checking inaccessible VM with UUID: {1d556a2c-47e8-4a38-9248-f4fe4afff07b}
Checking inaccessible VM with UUID: {be2624d1-1fef-4d79-a8fe-29dfc7cfc25f}
Checking inaccessible VM with UUID: {28d9ba27-5a53-4e76-be19-c3be75590269}
Checking inaccessible VM with UUID: {2d852b5c-20a4-43c8-a3b9-4bd6f9d5e55f}
Checking inaccessible VM with UUID: {62777438-b4f1-4114-a01a-c53e50390c79}
Checking inaccessible VM with UUID: {f85c6a6a-bac1-4464-b390-b3217dd83ea7}
Checking inaccessible VM with UUID: {7e622b84-3a81-4299-aea2-ad6ce00f3bd7}
Checking inaccessible VM with UUID: {31d7dcc3-38f3-4744-9b42-04b330f36038}
Checking inaccessible VM with UUID: {de2b3bb3-2e14-445e-b91f-2e09cb1d83f8}
Checking inaccessible VM with UUID: {94240573-4b89-45fa-905b-ef1299c965ec}
Checking inaccessible VM with UUID: {b823c11a-1c75-47be-bf19-fee746443a5e}
Checking inaccessible VM with UUID: {e0925b09-aad7-40c2-a8ec-aab3a73f7b9d}
Checking inaccessible VM with UUID: {56c05e9c-42da-4546-b3ef-bdbe3cef6186}
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium "C:\ProgramData\BOINC\slots\32\mainimage.vdi"
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\mainimage.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Mediun Info: UUID: 2e489d74-7dc4-486a-8a84-88abb9567796
Parent UUID: base
State: inaccessible
Access Error: UUID {483a3330-aa42-4a3d-8b44-83e27f077d7f} of the medium 'C:\ProgramData\BOINC\slots\32\mainimage.vdi' does not match the value {2e489d74-7dc4-486a-8a84-88abb9567796} stored in the media registry ('C:\Users\yvesc\.VirtualBox\VirtualBox.xml')
Type: normal (base)
Location: C:\ProgramData\BOINC\slots\32\mainimage.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 2048 MBytes
Size on disk: 1600 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
Child UUIDs: 3a97e755-2b56-4809-8dca-688ead16d06f
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" showmediuminfo 00d0f906-cb5f-43b2-b60d-8a59eb7138ce
**********************************************************
OUTPUT:
VBoxManage.exe: error: Could not find a registered machine with UUID {94bfdfb4-9ae0-48c7-96a9-8cbe5ae128d1}
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(machineIds[i], pMachine.asOutParam())" at line 1602 of file VBoxManageDisk.cpp
UUID: 00d0f906-cb5f-43b2-b60d-8a59eb7138ce
Parent UUID: b0b02692-d1c2-4ca6-94c1-9840a74d9913
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{00d0f906-cb5f-43b2-b60d-8a59eb7138ce}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{00d0f906-cb5f-43b2-b60d-8a59eb7138ce}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{00d0f906-cb5f-43b2-b60d-8a59eb7138ce}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 2048 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
**********************************************************
RETURN: -2135228415
*****************************VBOX ERROR*****************************
Unregistering medium: VBoxManage.exe: error: Could not find a registered machine with UUID {94bfdfb4-9ae0-48c7-96a9-8cbe5ae128d1}
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(machineIds[i], pMachine.asOutParam())" at line 1602 of file VBoxManageDisk.cpp
UUID: 00d0f906-cb5f-43b2-b60d-8a59eb7138ce
Parent UUID: b0b02692-d1c2-4ca6-94c1-9840a74d9913
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{00d0f906-cb5f-43b2-b60d-8a59eb7138ce}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{00d0f906-cb5f-43b2-b60d-8a59eb7138ce}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{00d0f906-cb5f-43b2-b60d-8a59eb7138ce}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 2048 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Unregistering medium: UUID: b0b02692-d1c2-4ca6-94c1-9840a74d9913
Parent UUID: 9010b53a-685a-49d4-bd71-0b781205a806
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{b0b02692-d1c2-4ca6-94c1-9840a74d9913}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{b0b02692-d1c2-4ca6-94c1-9840a74d9913}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{b0b02692-d1c2-4ca6-94c1-9840a74d9913}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 2048 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Child UUIDs: 00d0f906-cb5f-43b2-b60d-8a59eb7138ce
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium b0b02692-d1c2-4ca6-94c1-9840a74d9913
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{b0b02692-d1c2-4ca6-94c1-9840a74d9913}.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Unregistering medium: UUID: 9010b53a-685a-49d4-bd71-0b781205a806
Parent UUID: 0ba593ce-4f11-4da2-8caf-f7d2669b6705
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{9010b53a-685a-49d4-bd71-0b781205a806}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{9010b53a-685a-49d4-bd71-0b781205a806}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{9010b53a-685a-49d4-bd71-0b781205a806}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 2048 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Child UUIDs: b0b02692-d1c2-4ca6-94c1-9840a74d9913
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium 9010b53a-685a-49d4-bd71-0b781205a806
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{9010b53a-685a-49d4-bd71-0b781205a806}.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Unregistering medium: UUID: 0ba593ce-4f11-4da2-8caf-f7d2669b6705
Parent UUID: 3a97e755-2b56-4809-8dca-688ead16d06f
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{0ba593ce-4f11-4da2-8caf-f7d2669b6705}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{0ba593ce-4f11-4da2-8caf-f7d2669b6705}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{0ba593ce-4f11-4da2-8caf-f7d2669b6705}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 2048 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Child UUIDs: 9010b53a-685a-49d4-bd71-0b781205a806
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium 0ba593ce-4f11-4da2-8caf-f7d2669b6705
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{0ba593ce-4f11-4da2-8caf-f7d2669b6705}.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Unregistering medium: UUID: 3a97e755-2b56-4809-8dca-688ead16d06f
Parent UUID: 2e489d74-7dc4-486a-8a84-88abb9567796
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{3a97e755-2b56-4809-8dca-688ead16d06f}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{3a97e755-2b56-4809-8dca-688ead16d06f}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{3a97e755-2b56-4809-8dca-688ead16d06f}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 2048 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Child UUIDs: 0ba593ce-4f11-4da2-8caf-f7d2669b6705
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium 3a97e755-2b56-4809-8dca-688ead16d06f
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{3a97e755-2b56-4809-8dca-688ead16d06f}.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Unregistering medium: UUID: 2e489d74-7dc4-486a-8a84-88abb9567796
Parent UUID: base
State: inaccessible
Access Error: UUID {483a3330-aa42-4a3d-8b44-83e27f077d7f} of the medium 'C:\ProgramData\BOINC\slots\32\mainimage.vdi' does not match the value {2e489d74-7dc4-486a-8a84-88abb9567796} stored in the media registry ('C:\Users\yvesc\.VirtualBox\VirtualBox.xml')
Type: normal (base)
Location: C:\ProgramData\BOINC\slots\32\mainimage.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 2048 MBytes
Size on disk: 1600 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
Child UUIDs: 3a97e755-2b56-4809-8dca-688ead16d06f
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium 2e489d74-7dc4-486a-8a84-88abb9567796
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\mainimage.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium "C:\ProgramData\BOINC\slots\32\deb_port.vdi"
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\deb_port.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Mediun Info: UUID: b9d9b316-d293-4bb1-933e-f7d05c2319d3
Parent UUID: base
State: inaccessible
Access Error: UUID {a4b2379c-19f6-4a1c-817c-eb63927b885c} of the medium 'C:\ProgramData\BOINC\slots\32\deb_port.vdi' does not match the value {b9d9b316-d293-4bb1-933e-f7d05c2319d3} stored in the media registry ('C:\Users\yvesc\.VirtualBox\VirtualBox.xml')
Type: normal (base)
Location: C:\ProgramData\BOINC\slots\32\deb_port.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20 MBytes
Size on disk: 6 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
Child UUIDs: 2860e8ec-63fb-4d9a-841b-8e644f273205
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" showmediuminfo f1b33f89-230c-468c-9652-aac825192585
**********************************************************
OUTPUT:
VBoxManage.exe: error: Could not find a registered machine with UUID {94bfdfb4-9ae0-48c7-96a9-8cbe5ae128d1}
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(machineIds[i], pMachine.asOutParam())" at line 1602 of file VBoxManageDisk.cpp
UUID: f1b33f89-230c-468c-9652-aac825192585
Parent UUID: c9afa3b1-8b34-47ad-a766-345ed4c99e32
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{f1b33f89-230c-468c-9652-aac825192585}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{f1b33f89-230c-468c-9652-aac825192585}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{f1b33f89-230c-468c-9652-aac825192585}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
**********************************************************
RETURN: -2135228415
*****************************VBOX ERROR*****************************
Unregistering medium: VBoxManage.exe: error: Could not find a registered machine with UUID {94bfdfb4-9ae0-48c7-96a9-8cbe5ae128d1}
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(machineIds[i], pMachine.asOutParam())" at line 1602 of file VBoxManageDisk.cpp
UUID: f1b33f89-230c-468c-9652-aac825192585
Parent UUID: c9afa3b1-8b34-47ad-a766-345ed4c99e32
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{f1b33f89-230c-468c-9652-aac825192585}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{f1b33f89-230c-468c-9652-aac825192585}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{f1b33f89-230c-468c-9652-aac825192585}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Unregistering medium: UUID: c9afa3b1-8b34-47ad-a766-345ed4c99e32
Parent UUID: 5413f02e-214a-47cc-9727-6d60d04cb7e1
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{c9afa3b1-8b34-47ad-a766-345ed4c99e32}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{c9afa3b1-8b34-47ad-a766-345ed4c99e32}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{c9afa3b1-8b34-47ad-a766-345ed4c99e32}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Child UUIDs: f1b33f89-230c-468c-9652-aac825192585
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium c9afa3b1-8b34-47ad-a766-345ed4c99e32
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{c9afa3b1-8b34-47ad-a766-345ed4c99e32}.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Unregistering medium: UUID: 5413f02e-214a-47cc-9727-6d60d04cb7e1
Parent UUID: 3fc15f5e-2e39-47fc-9be6-4805f435e427
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{5413f02e-214a-47cc-9727-6d60d04cb7e1}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{5413f02e-214a-47cc-9727-6d60d04cb7e1}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{5413f02e-214a-47cc-9727-6d60d04cb7e1}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Child UUIDs: c9afa3b1-8b34-47ad-a766-345ed4c99e32
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium 5413f02e-214a-47cc-9727-6d60d04cb7e1
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{5413f02e-214a-47cc-9727-6d60d04cb7e1}.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Unregistering medium: UUID: 3fc15f5e-2e39-47fc-9be6-4805f435e427
Parent UUID: 2860e8ec-63fb-4d9a-841b-8e644f273205
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{3fc15f5e-2e39-47fc-9be6-4805f435e427}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{3fc15f5e-2e39-47fc-9be6-4805f435e427}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{3fc15f5e-2e39-47fc-9be6-4805f435e427}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Child UUIDs: 5413f02e-214a-47cc-9727-6d60d04cb7e1
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium 3fc15f5e-2e39-47fc-9be6-4805f435e427
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{3fc15f5e-2e39-47fc-9be6-4805f435e427}.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Unregistering medium: UUID: 2860e8ec-63fb-4d9a-841b-8e644f273205
Parent UUID: b9d9b316-d293-4bb1-933e-f7d05c2319d3
State: inaccessible
Access Error: Could not open the medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{2860e8ec-63fb-4d9a-841b-8e644f273205}.vdi'.
VD: error VERR_PATH_NOT_FOUND opening image file 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{2860e8ec-63fb-4d9a-841b-8e644f273205}.vdi' (VERR_PATH_NOT_FOUND)
Type: normal (differencing)
Auto-Reset: off
Location: C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{2860e8ec-63fb-4d9a-841b-8e644f273205}.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20 MBytes
Size on disk: 2 MBytes
Encryption: disabled
Property: AllocationBlockSize=
Child UUIDs: 3fc15f5e-2e39-47fc-9be6-4805f435e427
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium 2860e8ec-63fb-4d9a-841b-8e644f273205
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\USPEX_VMVASP_52769183\Snapshots\{2860e8ec-63fb-4d9a-841b-8e644f273205}.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Unregistering medium: UUID: b9d9b316-d293-4bb1-933e-f7d05c2319d3
Parent UUID: base
State: inaccessible
Access Error: UUID {a4b2379c-19f6-4a1c-817c-eb63927b885c} of the medium 'C:\ProgramData\BOINC\slots\32\deb_port.vdi' does not match the value {b9d9b316-d293-4bb1-933e-f7d05c2319d3} stored in the media registry ('C:\Users\yvesc\.VirtualBox\VirtualBox.xml')
Type: normal (base)
Location: C:\ProgramData\BOINC\slots\32\deb_port.vdi
Storage format: VDI
Format variant: dynamic default
Capacity: 20 MBytes
Size on disk: 6 MBytes
Encryption: disabled
Property: AllocationBlockSize=1048576
Child UUIDs: 2860e8ec-63fb-4d9a-841b-8e644f273205
This medium located in current folder (or in sudirectories of it): ÀåŤ
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" closemedium b9d9b316-d293-4bb1-933e-f7d05c2319d3
**********************************************************
OUTPUT:
VBoxManage.exe: error: Cannot close medium 'C:\ProgramData\BOINC\slots\32\deb_port.vdi' because it has 1 child media
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "Close()" at line 1875 of file VBoxManageDisk.cpp
**********************************************************
RETURN: -2135228404
*****************************VBOX ERROR*****************************
Creating VM...
Preparing VM...
Setting VM...
Applying modifications --memory 6144
Making storage controllers...
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" storageattach USPEX_VMVASP_52769183 --storagectl ide-controller_9744165289872471 --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC\slots\32\mainimage.vdi"
**********************************************************
OUTPUT:
VBoxManage.exe: error: UUID {35cfa11b-2a11-4f73-b37f-f0da9cfe9d35} of the medium 'C:\ProgramData\BOINC\slots\32\mainimage.vdi' does not match the value {2e489d74-7dc4-486a-8a84-88abb9567796} stored in the media registry ('C:\Users\yvesc\.VirtualBox\VirtualBox.xml')
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp
**********************************************************
RETURN: -2147467259
*****************************VBOX ERROR*****************************
Adopting state...
Starting VM...
*****************************VBOX ERROR*****************************
COMMAND: "C:\Program Files\Oracle\VirtualBox\VBoxManage.exe" startvm USPEX_VMVASP_52769183 --type headless
**********************************************************
OUTPUT:
VBoxManage.exe: error: piix3ide#0: The target VM is missing a primary master device. Please make sure the source and target VMs have compatible storage configurations [ver=20 pass=final] (VERR_SSM_LOAD_CONFIG_MISMATCH)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole
Waiting for VM "USPEX_VMVASP_52769183" to power on...
**********************************************************
RETURN: -2147467259
*****************************VBOX ERROR*****************************
Errors occured with starting VM. Exiting...
</stderr_txt>
]]>
©2025 USPEX TEAM